Title: Application of the Absorbable Hemostatic Gauze and Gelatin Sponge in the Practical Breast Cancer Surgery
Abstract: Objective: To observe the hemostatic effect of absorbable hemostatic gauze(Trade name: Tailing) and gelatin sponge in modified radical mastectomy and their impact on the amount of drainage and extubation time. Methods: 180 cases of breast cancer who were going to undergo modified radical mastectomy were randomly divided into 3 groups, the tailing group, gelatin sponge group and control group, 60 cases in each group, who were given Tailing, gelatin sponge and blank control after operation respectively, the fluid volume on the 1st, 2nd and 3rd postoperation, extubation time and total fluid volume were recorded and compared. Results: Compared with the control group, the fluid volume of Tailing group and gelatin sponge group on the 1st, 2nd and 3rd postoperation were obviously decreased, drainage liquid red blood cell count and total volume were decreased and extubation time obviously was shortened(P0.05). Compared with the gelatin sponge group, the fluid volume of Tailing group on the 1st, 2nd and 3rd postoperation, drainage liquid red blood cell count and total volume obviously were decreased and extubation time were shorten(P0.05). Conclusion: Tailing and gelatin sponge had good hemostatic effect after modified radical mastectomy of breast cancer, which reduced the postoperative bleeding, ooze blood, subcutaneous effusion and complications. Tailing had a better effect than gelatin sponger.
Publication Year: 2014
Publication Date: 2014-01-01