Title: STUDY ON THE OPTIMUM TECHNOLOGY OF THE SUPERCRITICAL CO_2 EXTRACTION OF PERILLA OIL
Abstract: Orthogonal contrast about 4 factors 3 levels of the main factors which haveinfluence on the extraction of perilla oil with supercritical CO, were studied. The resultsshowed that the optimum conditions were as follows: extrating in a pressure 20MPa at 40℃ for 6h with 30lL/h of CO2 flow.The yield of perilla,Oil was 37.2% and the content of α- lindenic acid was 73. 1 %.