Title: Flow rate measurement of oil-water two-phase flow based on V-cone flow meter
Abstract:In petroleum industry, oil-water two-phase flow widely exists in production wells, and the measurement of oil-water flow is significant in oil well logging. One method in common use is to build a theo...In petroleum industry, oil-water two-phase flow widely exists in production wells, and the measurement of oil-water flow is significant in oil well logging. One method in common use is to build a theoretic model to connect differential pressures generated by a throttling set with flow-rate. Several measuring models were adopted and compared for model selection and modification. A V-cone with 0.65 diameter ratio was selected as the throttling set because of its special structure and intrinsic advantages. In the experiments, the differential pressures measured under different flow range were processed with a homogeneous flow model. And the results show that the error is small in the condition where the oil and water are well mixed, while the error is big when they are not well mixed. A polynomial of the error and the water percentage was fitted to improve the model accuracy and widen the measurement range.Read More