Title: Calibration of the RLS HPGe spectral gamma ray logging system
Abstract: Gamma-ray spectral data have been recorded with the Radionuclide Logging System (RLS) high purity germanium (HPGe) system at (1) the American Petroleum Institute (API) spectral gamma-ray calibration center in Houston, Texas; (2) the US Department of Energy (DOE) spectral gamma-ray field calibration facility in Spokane, Washington; and (3) the DOE spectral gamma-ray primary calibration center in Grand Junction, Colorado. Analyses of the Grand Junction data yielded: calibration constants for the natural gamma-ray sources (potassium, uranium and thorium), energy-dependent borehole diameter corrections for the aid-filled borehole, energy-dependent borehole casing corrections for steel casing over a range of thicknesses from 0 to 79 cm (5/16 in.), a casing index function that varies with casing thickness and provides a method for verifying that the correct casing correction is applied, and an energy-dependent inverse function that is the basis for assessment of subsurface concentrations of man-made gamma-ray emitters such as cesium-137 and cobalt-60.
Publication Year: 1991
Publication Date: 1991-11-01