Title: Geological Structures and Their Relation to Groundwater System around K-1 Oil Stockpile
Abstract: The most serious problem in oil stockpiles with artificial underground cavern is maintaining the stability of ground water system. In order to understand the ground water system around K-1 site, we determined the regional flow direction and level distribution of groundwater, and investigated the major geologic factors influencing their flow system. Reactivated surface along the contact between granite and gneiss, and fractures and faults along the long acidic dyke may contribute as important pathways for groundwater flow. Within K-1 site, groundwater level fluctuation is closely related to the rainfall events and injection from surface or influx water. In this project, the effect of groundwater pumping from the southern wells was examined. Based on equations relating water level drawdown to pumping rate at those wells, their pumped outflow of groundwater ranged from /day to less than /day. The modeling results with MODFLOW imply that the previous groundwater pumping at distance of 1.2 km may not affect the groundwater level variations of the K-1 site. However, continuous pumping work at quantity over /day in this area will be able to affect the groundwater system of the K-1 site, particularly along the acidic dyke.