Title: Transmission Line Impedance Characterization Using an Uncalibrated Vector Network Analyzer
Abstract: For determining the line characteristic impedance Z <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> of uniform transmission lines, it is typically necessary to use a calibrated vector network analyzer (VNA), whose calibration reference impedance Z <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> is known. Using the eight-error term model for modeling a VNA and based on the fact that the values of the error terms are unique and independent of the calibration structures used to determine them, a new method for determining the line characteristic impedance of uniform transmission lines is presented. The main feature of the new method is that it only uses S-parameter measurements of a thru-line and a thru-load combination measured with an uncalibrated VNA.