Title: On the Pressure Drop and the Velocity Distribution in the Cylindrical Vortex Chamber with Two Inlet Pipes for the Control of Vortex Flow
Abstract:Vortex flow is applied to a cyclone dust collector, a vortex combustion chamber, and a vortex diode for vortex control. In order to apply the vortex flow to the industries, it is necessary to keep the...Vortex flow is applied to a cyclone dust collector, a vortex combustion chamber, and a vortex diode for vortex control. In order to apply the vortex flow to the industries, it is necessary to keep the stable flow condition and to estimate the response time of the transient flow process and also the intensity of the vortex flow. For control vortex flow, two types of vortex chamber with two inlet pipes were designed. One of them is to promote the vortex flow named as Co-Rotating Flow System and another one is to hinder the vortex flow named as Counter-Rotating Flow System. The pressure drops and the velocity distributions were measured for these vortex chambers. The estimation of the tangential velocity by the application of the angular momentum flux is compared with the measured velocity by a cylindrical Pitot-tube. The characteristics of the total pressure drop could be explained by introducing the circulation.Read More
Publication Year: 2005
Publication Date: 2005-01-01
Language: en
Type: article
Access and Citation
AI Researcher Chatbot
Get quick answers to your questions about the article from our AI researcher chatbot