Title: Evaluation of rural territorial functions: A case study of Henan Province, China
Abstract: A certain office building in Wuhan city was selected in this paper as an example of the hot summer and cold winter zone. The thermal environment simulation of the building was calculated by energy-saving analysis software Ecotect Analysis when the building external walls were, respectively, used by glass pumice external insulation system, glass pumice concrete block self-insulation system, and specified by limit requirements. The results show that building energy consumption, heat losses of envelope, and total discomfort value of two glass regenerated pumice external insulation systems can meet the requirements in specification. And compared with the pumice concrete block self-insulation external wall system, the glass pumice external insulation external wall building can be more effective for energy consumption, decrease envelope heat losses proportion, and reduce discomfort value caused by cold. The results will provide a reference to promote this environmentally material used for the wall insulation system in the energy conservation building in the region.
Publication Year: 2015
Publication Date: 2015-05-28
Language: en
Type: book-chapter
Indexed In: ['crossref']
Access and Citation