Title: Determination of Icariin in Shuxin Tablets by HPLC
Abstract: Objective: To establish a method for the determination of icariin in Shuxin tablets.Methods: A HPLC was used.Phenomenex BDS C18 column was 250mm×4.6mm,5μm.The mobile phase was acetonitrile-water(78:22).The flow rate was 1mL.min-1 with 25℃ of column temperature and 270nm of detected wavelength.Results: Icariin had a good linear relation at the range of 0.1972 ~1.972μg,r=0.9994,and average recycle rate was 99.91%,RSD was 2.75%.Conclusion: T The method is simple,sensitive and accurate and can be used for the determination of Icariin in making compound preparation.
Publication Year: 2009
Publication Date: 2009-01-01
Language: en
Type: article