Title: Determination of paeoniflorin in Baidai pills by HPLC
Abstract: OBJECTIVE To establish a HPLC method for the determination of the contentof Paeoniflorin in Baidai Pills.METHODS Kromasil 100-5C18(250mm×4.6mm)column was used,the mobile phase was methanol,rate was set at 1.0mL·min-1,the detection wave length was 230nm;and column temperature was room temperature.RESULTS The calibration curve was linear(r=0.9999,n=5)in the range of 0.9224~2.244μg for Paeoniflorin,the average recovery was 99.84% RSD was 0.34%(n=9).CONCLUSION This method may be accurate,sample sensitive and reliable and it can be ed as the quality control of Baidai pills.
Publication Year: 2007
Publication Date: 2007-01-01
Language: en
Type: article