Title: System of Coagulant Dosage Control in the Micro-coagulant Filteration
Abstract: In this paper,the SCD technique has been systematically analyzed and studied by theoretical research associated with application.The experiment results indicate:Generally,the reservoir's water (turbidity of the raw water resource no more than 20 ntu) streaming current set point ( S p) should be -17.5;The process time of dosing pipe line is 50~60 seconds;The flow rate of sampling and dosing system should be fixed (this test adopt q 出=2.6 ml·min -1 ).The experiment results point out that the coagulant dosage control technique by the SCD is satisfactory and practicable with micro coagulant filteration of the raw water from the reserviors.