Title: Design Method of Semi-Rigid Composite Beam-to-Column Joints with Flush End Plate Connections
Abstract: The beam-to-column joints are assumed to be rigid or pinned in the traditional method for design and analysis. But in fact,most of the connections are semi-rigid,whose characters are between the pinned and rigid,since it is very difficult to realize full pinned and rigid. In the composite frames,a new type connection called semi-rigid composite connection,composed of bare steel joint and composite slab is achieved. Based on the current available research,a design method of semi-rigid composite beam-to-column with flush end plate connections is put forward aiming at the lack of design method in building codes of our country in this paper. This method can provide a reference when revising the corresponding building codes.
Publication Year: 2010
Publication Date: 2010-01-01
Language: en
Type: article
Access and Citation