Abstract: In this paper the tungsten contamination in ion implantation processes is studied by DLTS analysis both in typical operating conditions and after contamination of the implanter by implantation of wafers with an exposed tungsten layer. Of course the contaminant concentration is orders of magnitude higher after contamination of the implanter, but in addition our data show that different mechanisms are active in a not contaminated and in a contaminated implanter. A moderate tungsten contamination is observed also in a not contaminated implanter, however in that case contamination is completely not energetic and can be effectively screened by a very thin oxide. On the contrary, the contamination due to an implantation in a previously contaminated implanter is reduced but not suppressed even by a relatively thick screen oxide. The comparison with SRIM calculations confirms that the observed deep penetration of the contaminant cannot be explained by a plain sputtering mechanism.
Publication Year: 2016
Publication Date: 2016-04-25
Language: en
Type: article
Indexed In: ['crossref']
Access and Citation
Cited By Count: 2
AI Researcher Chatbot