Title: The removal of COD from refinery wastewater by Fenton reagent
Abstract: Chemical oxygen demand (COD) has been the crucially problematic parameters in refinery wastewater treatment. This study was conducted to investigate COD removal in refinery wastewater with Fenton process. The effects of pH value, H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> dosage, the mole ratio of Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> to H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , oxidation time and oxidation temperature on COD removal were discussed. The results showed that COD removal efficiency first increased then decreased with the increase of solution pH, and the highest COD removal appeared as pH was about 2.5 to 3.0. The COD removal rose from 36.61 % to 43.44 % with H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> concentration from 25 mmol-L1 to 60 mmol-L"1. The COD removal first increased then decreased with the mole ratio of Fe <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> to H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> . The maximum COD removal appeared as the mole ratio of Fe to H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> is 1:5. The COD removal increased with time and leveled off after 120 minutes. When the oxidation temperature increased from 30°C to 50°C, the COD removal increased slightly from 40.98% to 44.81%.
Publication Year: 2011
Publication Date: 2011-06-01
Language: en
Type: article
Indexed In: ['crossref']
Access and Citation
Cited By Count: 6
AI Researcher Chatbot
Get quick answers to your questions about the article from our AI researcher chatbot