Title: Performance enhancement of a diffusion-absorption refrigerator
Abstract: An effort was undertaken to improve the current cycle performance of the diffusion-absorption refrigerator (DAR). The thermodynamic basis for the design changes is to reuse waste heat from the rectifier to heat the weak absorbent from the absorber. A new generator with heat exchanger (GWHX) was designed and fabricated. The test results of the DAR with GWHX are compared with baseline tests. The new generator design demonstrated a significant improvement in the cooling COP of as much as 50% compared to the baseline tests while the cooling capacity was unchanged. On a essayé d'améliorer la performance d'un réfrigérateur à cycle diffusion-absorption. Selon la base thermodynamique adoptée, on a réutilisé la chaleur perdue du rectificateur pour chauffer la solution riche en ammoniac (absorbat) et pauvre en eau (absorbent) sortant de l'absorbeur. On a conçcu et fabriqué un nouveau générateur comportant un échangeur de chaleur. On a comparé les résultats expérimentaux relatifs au réfrigérateur à diffusion-absorption, pourvu d'un générateur aver échangeur de chaleur, avee des données expèrimentales de référence. Cette nouvelle conception du générateur a permis d'améliorer considérablement le COP de refroidissement, de l'ordre de 50%, par rapport aux résultats de référence, sans que cela n'affecte la capacité de refroidissement.