Title: Patient Controlled Analgesic Therapy in the Early Postoperative Period
Abstract:Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia...Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia and the postoperative self-administration period, and the concentrations of pethidine and nor-pethidine were determined. Separate single-dose studies in eight patients yielded pharmacokinetic parameters which made possible computer simulations of continuous plasma concentration curves for the anaesthesia and postoperative self-administration period. The consumption of pethidine showed great interindividual variations with a mean consumption for the entire group of 26 mg per hour. The patients established steady-state plasma concentrations with far less than the maximum amount of pethidine allowed. The mean measured plasma concentration of pethidine which provided adequate analgesia was 738 +/- 149 ng/ml. Simulated and measured plasma concentrations were in close agreement. The individual mean drug consumption per hour during self-administration correlated closely with the individual elimination rate of pethidine. No serious side effects were observed. Thus, patient-controlled analgesic therapy offers an individualized analgesic supply to meet an analgesic demand which is governed by each patient's appreciation of pain.Read More
Publication Year: 1979
Publication Date: 1979-10-01
Language: en
Type: article
Indexed In: ['crossref', 'pubmed']
Access and Citation
Cited By Count: 83
AI Researcher Chatbot
Get quick answers to your questions about the article from our AI researcher chatbot
Title: $Patient Controlled Analgesic Therapy in the Early Postoperative Period
Abstract: Fourteen patients with postoperative pain were allowed to self-administer preset doses of pethidine intravenously via a logic-controlled motor syringe. Plasma samples were collected during anaesthesia and the postoperative self-administration period, and the concentrations of pethidine and nor-pethidine were determined. Separate single-dose studies in eight patients yielded pharmacokinetic parameters which made possible computer simulations of continuous plasma concentration curves for the anaesthesia and postoperative self-administration period. The consumption of pethidine showed great interindividual variations with a mean consumption for the entire group of 26 mg per hour. The patients established steady-state plasma concentrations with far less than the maximum amount of pethidine allowed. The mean measured plasma concentration of pethidine which provided adequate analgesia was 738 +/- 149 ng/ml. Simulated and measured plasma concentrations were in close agreement. The individual mean drug consumption per hour during self-administration correlated closely with the individual elimination rate of pethidine. No serious side effects were observed. Thus, patient-controlled analgesic therapy offers an individualized analgesic supply to meet an analgesic demand which is governed by each patient's appreciation of pain.