Title: A “one-minute” direct bilirubin determination using the Abbott ABA-100 bichromatic analyser
Abstract: We describe a “one-minute” direct bilirubin procedure using the ABA-100. The procedure correlates well with the manual Jendrassik-Grof method and gives good precision at a relatively low direct bilirubin level. In comparison with certain other Abbott ABA-100 direct bilirubin methods, the proposed procedure appears to be the least affected by the presence of high uncojugated bilirubin levels.
Publication Year: 1982
Publication Date: 1982-04-01
Language: en
Type: article
Indexed In: ['crossref', 'pubmed']