Title: A Study of Near Field Shielding Effect Measurement for Oval Human Phantom Model using the Conductive Material Shield
Abstract:In this study, the near field human shield is investigated, which measured the shielding effect of the oval human phantom model, by locating the conductive material shield in front of the phantom mode...In this study, the near field human shield is investigated, which measured the shielding effect of the oval human phantom model, by locating the conductive material shield in front of the phantom model. Also the shielding effect is investigated with the FDTD (Finite Difference Time Domain) method, to confirm the validity of the measurement method. According to the results, it has been shown, that more than 30 dB of the shielding effect is observed for the small gap distances between the shield and phantom model, with the square shield length of 1.0 λ. On the other hand, very little and also negative shielding effect observed for the square shield length of 0.25 λ. Furthermore, due to the good agreement between the measured and calculated results, the validity of our measurement method is confirmed.Read More
Publication Year: 2000
Publication Date: 2000-10-01
Language: en
Type: article
Indexed In: ['crossref']
Access and Citation
Cited By Count: 2