Title: Impurity concentrations of niobium and molybdenum in the Japanese steel F82H-mod by activation analysis
Abstract: An activation experiment with 19.5 MeV α-particles was made in order to check the niobium and molybdenum impurity concentrations of the Japanese steel F82H-mod. The γ-spectroscopic analysis yielded a concentration of (2.5 ± 1.0) wt. ppm niobium and of (46 ± 17) wt. ppm molybdenum. These values are in good agreement with the manufacturer's data being 1 wt. ppm niobium and 30 wt. ppm molybdenum.
Publication Year: 1997