Title: Analysis of Orifice Plate Differential Pressure Noise in Horizontal and Vertical Rising Gas-Water Two-Phase Flow
Abstract:It is an important achievement of modern techniques to determine the mass flow rate and the phase fraction of wet steam by measuring the orifice plate differential pressure noise. The orifice plate di...It is an important achievement of modern techniques to determine the mass flow rate and the phase fraction of wet steam by measuring the orifice plate differential pressure noise. The orifice plate differential pressure noise of air-water two-phase flow in horizontal and vertical rising pipelines were analyzed. Kinds of calculation methods were tried to get the differential pressure noise. From the difference waveform of the differential pressure square root that the acquisition card got and the mean square root of the sample that got before, the first in first out (FIFO) principle was used to get the differential pressure noise. Result shows that the differential pressure noise has different level at different vapor flow rate with the same water flow rate, conclusions show that the two-parameter measurement by using orifice plate differential pressure noise may be possibly used in vertical rising gas-water two phase flow.Read More
Publication Year: 2010
Publication Date: 2010-01-01
Language: en
Type: article
Indexed In: ['crossref']
Access and Citation