Title: Soft-switched inverter by a DC chopper with resonant snubber
Abstract:This paper presents a new method implementing a soft-switched inverter which is formed by a conventional inverter and a DC chopper with a resonant snubber. When the inverter commutates, the chopper ma...This paper presents a new method implementing a soft-switched inverter which is formed by a conventional inverter and a DC chopper with a resonant snubber. When the inverter commutates, the chopper makes the voltage across the inverter zero; thus the inverter works under soft-switching conditions. An amount of the chopper switched-aid circuit energy can be recovered by the resonant snubber design. Simulated and experimental results are given.Read More
Publication Year: 2002
Publication Date: 2002-11-22
Language: en
Type: article
Indexed In: ['crossref']