Title: LiF and CaF2:Mn thermoluminescent dosimeters in tandem
Abstract: Thermoluminescent dosimeters employing two or more different phosphors can be used for measuring the dose from different components of a radiation field. In particular two phosphors of differing atomic numbers can be utilized to measure the effective energy of an X- or γ-ray field. If their glow-peak temperatures differ sufficiently, or if a time delay can be applied to the heating of one or the other phosphor, their thermoluminescence signals can be separately measured in a single heating operation. The resulting combined glow curve contains, in peak height or area of either glow-peak, the dose or exposure reading. The ratio of peak heights (or areas) yields the effective energy. Such a tandem dosimeter, employing extruded LiF (TLD-700) and hot-pressed CaF2:Mn, has been constructed and its performance explored. Les dosimétres thermoluminescents qui emploient deux ou plus différents phosphores peuvent servir à mesurer la dose de différents composants d'un champ de rayonnement. En particulier deux phosphores de différents nombres atomiques peuvent s'employer à la mesure l'énergie effective d'un champ de rayons X ou γ. Si les températures des pics de luisance sont assez différentes, ou si l'on peut imposer un retard au chauffage de l'un ou l'autre des phosphores, leurs signaux de thermoluminescence peuvent être mesurés séparément en une seule opération de chauffage. La courbe de luisance combinée qui en résulte contient, en la hauteur des pics ou en l'aire de chaque pic de luisance, la mesure de la dose ou de l'exposition. Le rapport des hauteurs (ou des aires) des pics rend l'énergie effective. On a construit un tel dosimètre “en tandem”, utilisant du LiF extrudé (TLD-700) et du CaF2:Mn pressé à chaud, et on a étudié so efficacité. TepMoлюMиHecцeHTHыeдoзиMeTpы, yпoTpeбляющиe дBa или бoлee paзлиkHыx фocфopa, MoгyT пpиMeHяTья для изMepeHия дoз paзHыx cocTaBHыx kacTeй пoля излykeHия. B kacTHocTи дBa фocфopa c paзллkHыMи aToMHыMи HoMepammcy;и MoгyT быTь иcпoльзoBaHы для изMepeHия эффeкTиBHoй эHepгии пoля peHTгeHovvcy;cкиx или гaMMa-лykeй. Ecли иx TeMпepaTypы MaкcиMaльHoгo cBekeHия дocTaTochcy;Ho paзлиkHы, или ecли зaпoздaHиe MoжeT быTь пpиMeHeHo к HaгpeBy Toгo или дpyгoгo фocфopa, иx TepMoлюMиHecцeHTHыe cигHaлы MoгyT быTь изMepeHы oTдeльHo пpи eдиHиkHoM HaгpeBaHии. PeзyльTиpyющaя кoMбиHипoBaHHaя кpиBaя cBekeHия бyдeT coдepжaTь пoкaзaHиe дoзы или oблykeHия B MaкcиMaльHoй BыcoTe или пpocTpaHcTBe любoгo MaкcиMaьoгo cBekeHия. CooTHoшeHиe MaкcиMaльHыx BыcoT (или пpocTpaHcTB) дaeT эффeкTиBHyю эHepгию. Был cкoHcTpyиpoBaH Taкoй дoзиMeTp пocлeдoBaTeльHoгo coeдиHeHия, yпoTpeбляющий экcTpyдиpoBaHHый LiF (TЛД-700) и пpeccoBaHHый пpи HaгpeBaHии CaF2:Mn. Thermoluminiszente Dosismesser mit zwei oder mehr verschiedenen Leuchtstoffen können verwendet werden, un die Dosis von verschiedenen Komponenten eines Bestrahlungsfeldes zu messen. Besonders können zwei Leuchtstoffe mitverschiedenen Atomzahlen verwendet werden, um die effektive Energie eines Röntgenstrahlen- oder Gammastrahlen-Feldes zu messen. Wenn sich ihre Spitzenglimmtemperaturen genügend unterscheiden oder wenn eine zeitliche Verzögerung beim Heizen eines der beiden Leuchtstoffe eingeführt werden kann, so können ihre Thermoluminiszenzsignale getrennt in einem einzigen Heizvorgang gemessen werden. Die erhaltene kombi-nierte Glimmkurve enthält in der Spitzenhöhe oder Fläche eines der Glimmspitzen die Dosis oder Bestrahlungsanzeige. Das Verhältnis der Spitzenhöhen (oder Flächen) ergibt die effektive Energie. Solch ein Doismesser in Serienschaltung mit stranggepresstem LiF(TLD-700) und warmgepresstem CaF2:Mn ist gebaut worden und seine Leistungsfähigkeit wird erforscht.
Publication Year: 1968
Publication Date: 1968-02-01
Language: en
Type: article
Indexed In: ['crossref', 'pubmed']
Access and Citation
Cited By Count: 40
AI Researcher Chatbot
Get quick answers to your questions about the article from our AI researcher chatbot