Title: Comparative Study Between 2 Methods of Mounting Models in Semiadjustable Articulator for Orthognathic Surgery
Abstract: Purpose Compare the traditional method of mounting dental casts on a semiadjustable articulator and the new method suggested by Wolford and Galiano, 1 analyzing the inclination of maxillary occlusal plane in relation to FHP. Materials and Methods Two casts of 10 patients were obtained. One of them was used for mounting of models on a traditional articulator, by using a face bow transfer system and the other one was used to mounting models at Occlusal Plane Indicator platform (OPI), using the SAM articulator. After that, na analysis of the accuracy of mounting models was performed. The angle made by de occlusal plane and FHP on the cephalogram should be equal the angle between the occlusal plane and the upper member of the articulator. Results The measures were tabulated in Microsoft Excell® and calculated using a 1-way analysis variance. Statistically, the results did not reveal significant differences among the measures. Conclusion OPI and face bow presents similar results but more studies are needed to verify its accuracy relative to the maxillary cant in OPI or develop new techniques able to solve the disadvantages of each technique. Compare the traditional method of mounting dental casts on a semiadjustable articulator and the new method suggested by Wolford and Galiano, 1 analyzing the inclination of maxillary occlusal plane in relation to FHP. Two casts of 10 patients were obtained. One of them was used for mounting of models on a traditional articulator, by using a face bow transfer system and the other one was used to mounting models at Occlusal Plane Indicator platform (OPI), using the SAM articulator. After that, na analysis of the accuracy of mounting models was performed. The angle made by de occlusal plane and FHP on the cephalogram should be equal the angle between the occlusal plane and the upper member of the articulator. The measures were tabulated in Microsoft Excell® and calculated using a 1-way analysis variance. Statistically, the results did not reveal significant differences among the measures. OPI and face bow presents similar results but more studies are needed to verify its accuracy relative to the maxillary cant in OPI or develop new techniques able to solve the disadvantages of each technique.
Publication Year: 2011
Publication Date: 2011-04-20
Language: en
Type: article
Indexed In: ['crossref', 'pubmed']
Access and Citation
Cited By Count: 6
AI Researcher Chatbot
Get quick answers to your questions about the article from our AI researcher chatbot